Re: Montecarlo: correlation parameter value for matched pairs?
by Riad KACED <riad.kaced@[EMAIL PROTECTED]
>
Sep 2, 2008 at 04:36 PM
Hi Jorge,
This is rather a tricky question :-(
It think this is more related to the experience with the process
itself. It's really something you should discuss with the process
engineers from your foundry. It might be helpful to ask for the test
structures that have been used to extract the MC matching data and
then compare them to your structure/Application ... etc. I don't think
there is a proven solid science behind this. It's rather something
related to the feeling and the appreciation of the IC designers based
on their experience on both the process and the application. I'm not
able to propose any number for this I'm afraid. The default (i.e no
correlation) is of course the most pessimistic scenario ...
That was my attempt anyway !
let's see what other chaps think about it ...
Cheers,
Riad.