Talk About Network

Google





Computer Aided Design - CAD > Cadence > Re: simulation ...
Latest [ Topics | Posts ] Archive Post A New Topic Post a Reply
<< Topic < Post Post 3 of 3 Topic 3986 of 4397
Post > Topic >>

Re: simulation results do not update

by Andrew Beckett <andrewb@[EMAIL PROTECTED] > May 8, 2008 at 10:44 AM

Riad KACED wrote, on 05/05/08 20:36:
> Hi Danniel !
> 
> That's a very odd behaviour !
> Have you got any error/warning message into your Spectre Log or CIW
> log ?
> That's strange ...
> 
> Riad.

Danniel,

I'm aware of your issue through customer sup****t - in fact I suggested
using 
"batch" mode to the AE sup****ting you.

Using "batch" mode does not cause a re-netlist, by the way. It just means
that 
spectre will re-start every time you run. In this specific case it would
have 
re-started because the analyses changed.

What should be happening is that a message to spectre should be getting
through 
to tell it to restart, but that's obviously not happening for some obscure
reason.

There's a log file that you could look at - I'll suggest that to the AE
who is 
handling your SR.

Regards,

Andrew.
 




 3 Posts in Topic:
simulation results do not update
danniel <danniel@[EMAI  2008-05-04 05:01:12 
Re: simulation results do not update
Riad KACED <riad.kaced  2008-05-05 12:36:30 
Re: simulation results do not update
Andrew Beckett <andrew  2008-05-08 10:44:12 

Post A Reply:
  Go here to Signup

AddThis Feed Button


About - Advertising - Contact - Frequently Asked Questions - Privacy Policy - Terms of Use - Signup

Contact
localhost-V2008-12-19 Fri Jan 9 12:55:11 PST 2009.